1. Riser type specification

1.1. Data group identifier, one input line

NEW SINGle RISEr

1.2. Selection of riser type and identifier

ATYPS IDRIS IDCON
  • ATYPS: character(6): Riser code type for single riser. Allowable codes are listed below: - SA: Next data in Standard system SA - SB: Next data in Standard system SB - SC: Next data in Standard system SC - SD: Next data in Standard system SD - AR: Next data in Standard system AR

  • IDRIS: character(6): Riser identifier

  • IDCON: character(6), deault: "NONE": Normally not used!

    • =LAYFLX - Roller contact forces are dumped on data files for LAYFLEX post-processing.

    • Static roller contact forces will be output to the file prefix_consta.asc.

    • For nonlinear dynamic analysis, time series of roller contact results will be stored on the file prefix_contts.asc and key results will be stored on the file prefix_condyn.asc.

One or several riser specifications may be created and stored by one run of INPMOD. The identifier IDRIS is used by STAMOD to select one particular riser for analysis.