External Wrapping This component can be used to model additional weight or buoyancy modules attached to a riser line. The specified additional weight and buoyancy are used to adjust the average properties of the segment. External buoyancy of weight elements that are clamped to the pipe are specified as external wrapping. External wrapping cannot be specified for segments consisting of the cross sections Double Symmetric Cross Section and Fish Net.