SIMA 5.4.0 Release Notes

Release highlights

Bladed-SIMA coupling

A new co-simulation coupling links DNV Bladed and SIMA for analysing floating offshore wind turbines. It enables modelling of the wind turbine in Bladed combined with modelling of the floater and mooring system in SIMA. Bladed integrates the floater motion, and at every time step SIMA returns the hydrodynamic and mooring loads on the floater.

Bladed-SIMA co-simulation conceptual sketch
Figure 1. Bladed-SIMA co-simulation conceptual sketch

See Bladed coupling for model requirements, setup and an example.

Run simulations and access results in Python

SIMAPy, the SIMA Python library, can now run a condition and return its results to Python in one function call:

from pathlib import Path
from simapy.sre import SIMA

sima = SIMA()
res = sima.run_condition(
    Path("output/beam"),                 # the workspace SIMA runs in
    task="SimpleBeam",
    condition="Initial",
    run_type="dynamic",
    variables={"Hs": 3.0, "Tp": 6.0},
)

peak = res.run.signal("Dynamic/BeamLine/segment_1/element_1/Axial force").y.max()

This enable users who use SIMA from Python to run simulations and anlyse results without detailed knowlegde of the data formats and folder structures used by SIMA. It is also possible to open results from a completed simulation with the new open_results function. See SIMAPy - Reading results for details.

New 3D visualization engine

The 3D views in SIMA now use a new visualization engine. This is mostly an internal change, but performance is improved particularly when visualizing large models. Some objects may look slightly different.

Improved rotation handling in 3D view

Right-click and drag in the 3D view now keeps the horizon level while you rotate, instead of letting the view tilt off-axis. In addition, an option has been added to roll the view around the current camera direction by holding Ctrl while dragging with the right mouse button.

New features

RIFLEX

New derived values for Stress storage

For Stress storage, outer diameter, thickness, internal pressure and external pressure may now be left unset (indicated by the text "default" in the field). SIMA then takes the diameter and thickness from the thin-walled pipe or axisymmetric cross section, and the pressures from the static simulation results. See Stress storage for details.

New Default file format for RIFLEX dynamic result storage

All RIFLEX dynamic result types have a new File format, "Default", which is the recommended choice for best compatibility and simulation performance. Stress storage requires forces to use it, and the new result reading functionality in SIMAPy reads only this format. Existing models keep their current file formats; use "Set all storage formats to default" on the Storage tab to switch a whole model. The "HDF5" option is replaced by "Default", and results that used it are converted automatically.

Mode shapes from eigenvalue analysis

The eigenvalue analysis can now store the rotations and an estimated curvature of the mode shapes as a result, in addition to the displacements. Curvature is estimated from the difference in nodal rotations divided by the element length. See Eigenvalue Calculation Parameters for details.

Choose the geometry of a nodal component

A nodal body, ball joint, flex joint or drag chain can now be drawn with a geometry of your own instead of the automatic sphere.

Improved error and warning messages for boundary change

The error message regarding a boundary change for a node attached to a flex-joint will now refer to the line, segment and local node instead of the FE node.

A warning will be given for a boundary change for a node attached to a ball joint. This is because the ball joint introduces a new element into the FE model and a line, segment and local node specification may not give the expected result.

A warning will also be given if a boundary change frees a node that is already free.

Improved header in the external controller log file

The header of the external controller log file now has one line per column, giving the signal name and unit. For nodal and element measurements, the node or element number and the coordinate system are also given. See Log file (External controller) for details.

Envelope curve storage

A new option to select the amount of data stored for envelope curve output is added. The added option is: "Min, max, mean, standard deviation".

Axis labels in more RIFLEX results

Some plots of RIFLEX results previously only showed the unit. They now show the proper axis label together with the unit, e.g. "Effective tension [N]" instead of only "[N]". Quantities without a unit, such as skewness, are shown as [-].

SIMO

Thruster forces are shown in the 3D result view

When results are animated in the 3D view, each SIMO thruster now shows the force it delivers as an arrow that follows its size and direction. Use Select vector results > Thruster force in the context menu to show or hide the arrows, and Set Arrow Scale to change their length.

The deprecated SIMO 4.0 thruster and DP formulation has been removed

Models and SIMO input files that use it are converted to the new formulation when opened or imported. Settings with no counterpart are dropped: dead band, minimum direction change, allocation weights and forbidden zones. See Thruster for the remaining thruster model.

Other

Examples moved to the web

SIMA examples have been moved online and are now accessible directly through the web, rather than being bundled with the installation. The Help menu now has an Examples > Open Examples item, which opens the examples web page inside SIMA. Clicking on an example in the internal browser will automatically download and add it to the workspace. See SIMA Examples.

Scripts can now be included in the clipboard export

When a table contains scripted cells, "Export" and "Export with headers" now ask whether to include the scripts. Choosing Yes writes each script as ":expression". This is the same form the Import from clipboard option already uses, so scripts can now be copied in and out of a table. Choosing not to include scripts export the computed values as before. Copying with Ctrl+C always exports computed values and never asks.

Signal selection query

The Use Query option is now available on the Signal Selection operation in Workflow and Post Processor. It works the same way as on connections.

Resolved issues

RIFLEX

Stress-free configuration from file

The static analysis may be started from a stress-free configuration read from an input file. The option is useful for effective modelling of pre-bent sections.

When the stress-free configuration was read from file (Stress free configuration file), the analysis stopped without an error message. This is now corrected.

3D animation for a dynamic analysis that fails

The 3D animation of a dynamic analysis that stopped part way through with an error only showed a single frame instead of showing the animation up to the point of failure. This has now been resolved.

Error since SIMA 5.2.0.

Memory leak when using HDF5 File format

Memory use grew steadily through a dynamic analysis that stored results in HDF5 format. This has now been resolved.

Stress storage for bar elements

If the cross section was a bar element, stress storage would fail. This is now corrected.

Stress storage and pipe stress calculation

The torsion and the shear force were previously neglected in the calculation of shear stress. The contribution from torsion and shear force to the shear stress is now accounted for using a approximation. The approximation is valid for a circular cross section with uniform cross sectional properties.

First time step of dynamic RIFLEX results in the 3D view

When 3D visualization Start time was larger than 0.0, the first step showed the static configuration, and every step was labelled one storage increment late.

Element forces adjacent to flex joints in frequency-domain VIV analysis

Corrected an error in the calculation of element forces for elements connected to a flex joint on an intermediate segment of a line. The response of the constrained degrees of freedom of the flex joint was not included, giving incorrect forces for the adjacent elements. This applied to frequency-domain VIV analysis (VIVANA) only.

Specified nodal loads at flex-joint nodes

A specified nodal load at a node attached to a flex joint entered the FE model incorrectly, due to an error in the coordinate transformations. An error was only given if the node had skew boundary conditions, e.g. if the flex-joint degrees of freedom were referred to the local flex-joint system.

Specified nodal loads, static or dynamic, at nodes attached to a flex joint are not allowed. An error message is now always given, and the analysis is stopped.

SIMO

Wave drift current correction mixed data between bodies

In a model with more than one body, the wave drift current correction could give a body another body’s corrected QTF, wave drift force or wave drift damping.

A model was affected if it had two or more bodies needing the correction, with a non-zero current, and the bodies did not all produce the same results — and only bodies listed after the body they inherited from. In practice that means:

  • a body with only wave drift force coefficients, listed after a body with a difference-frequency QTF, was given that QTF;

  • a body with a difference-frequency QTF, listed after a body with only wave drift force coefficients, was given those coefficients;

  • a body without wave drift damping, listed after a body whose damping is computed from its QTF or wave drift force, was given that damping.

Wave drift damping generated silently for new QTF model

A SIMO body with a file-based difference-frequency QTF and wave-current interaction enabled no longer has a wave drift damping model added without being asked. To compute damping from a file-based QTF, add a Wave drift damping object and set From to QTF. The unintended generation was introduced in SIMA 5.2.0. Few models should be affected, since SIMA already showed a validation warning recommending a wave drift damping model for this combination.

Wave drift damping computed from QTF on file

When using Aranha’s method to compute Wave Drift Damping from a full QTF, SIMO always failed with "Could not read rank". This has now been resolved.

Current heading in the wave-current (Aranha) correction for new QTF model

A unit mismatch caused the current direction relative to the wave to be interpreted as radians instead of degrees.

Affected: models with a difference-frequency QTF read from file (QTF input mode File) with Enable wave-current interaction switched on, in a condition where the current is non-zero and not aligned with the waves. For these, the wave drift damping derived from the QTF was wrong and reached the simulation, and the wave-current correction preview in the QTF plot showed incorrect curves.

Names and units of SIMO wave drift damping force results

The wave drift damping force channels were named and stored as if they were coefficients for the first wave direction ("B11_1 coeff …​"). That gave each one a duplicate name, and the force components got the wrong units. The force components are now stored as forces and moments in their own channels, with units of force or force·m, next to the direction-dependent damping coefficients.

Tabs in files for prescribed body motion

Using tabs as a number separator in files for prescribed body motion would previously make the simulation crash. This has now been resolved and tabs are now supported as a number separator making copying data from e.g. Excel easier.

Missing validation of Tc Azimuth for thrusters

It is now validated that Tc Azimuth on the Thruster model is larger than zero.

Other

Polynomial fit now covers the whole signal

The Polynomial Fit operation in Workflow and Post Processor returned only as many values as the polynomial had coefficients. A fit of power 3 produced three points no matter how long the input signal was. It now returns one value per input sample. Subtracting the fit from the original signal likewise now covers the whole signal instead of only its first few samples.

Post processors using this operation produce longer results than in previous versions.

Known issues

RIFLEX

Incorrect unit for mechanical brake in wind turbine shutdown

The Linear Torque Damping Coefficient of the mechanical brake in a wind turbine shutdown is entered in N·m·s/deg, but incorrectly depends on the choice of Export Mass Unit in the Task editor. With Mg (the default), the value is treated as kN·m·s/deg, so the brake torque is 1000 times too large. When this is corrected, the field will take input as N·m·s/deg.

SIMO

Incorrect force unit stated in the External Force From File editor

The External Force From File editor states that the forces in the file are given in kN. This is only correct when Export Mass Unit in the task is Mg. SIMO reads the file in the force unit of the task: with Mg, forces are in kN and moments in kN·m; with kg, forces are in N and moments in N·m.

Deprecated functionality

The following functionality has been deprecated and will be removed in a future release of SIMA.

SIMO

Use Old Result Structure result storage option

This option make sure that simulation results from SIMO use the same names as in releases before SIMA 5.2.0. The option is scheduled for removal in SIMA 5.8.0.

The consequence of this removal is that names of results from old models that relied on this option will change. Any post processing and/or workflows that rely on old result names have to be updated to continue working. The result file results.tda will no longer be generated by SIMO.

Soil Penetration on Small Volume Hydrodynamics

The Soil Penetration model on Small Volume Hydrodynamics is deprecated and is scheduled for removal in SIMA 5.8.0.