Hydrodynamic force coefficients The Hydrodynamic force coefficients tab selects the hydrodynamic load model of the cross section and gives its coefficients. The tab is used by the axisymmetric, thin-walled pipe, coupled axial-torsion, armoured and fibre rope cross sections. The fields shown depend on the load model and on the input code. 1. Load model Load formulation: The hydrodynamic load model of the cross section. The options available depend on the cross-section type, see Hydrodynamic load models. Morison: Morison’s generalized equation. Morison partly submerged cross section: Morison’s equation for partly submerged, floating elements. Time domain VIV: Morison’s equation with time domain VIV loads. MacCamy-Fuchs with quadratic drag: MacCamy-Fuchs load model. Potential flow with quadratic drag load coefficients: Potential flow. Net: Net loads. None: No hydrodynamic loads. The rest of this page describes the coefficients for the three Morison-type models: Morison, Morison partly submerged cross section and Time domain VIV. The other load models use a subset of the same fields. 2. Input code The coefficients are given either as dimensional coefficients, which are used directly in the load calculation, or as nondimensional coefficients, which are converted to dimensional coefficients using the water density and the hydrodynamic diameter. Froude-Krylov scaling: Select to scale the Froude-Krylov term in Morison’s equation, see Froude-Krylov scaling. Input code: How the coefficients are given. Dimensional coefficients: Coefficients per unit length, with units. This is the default. Nondimensional coefficients: Nondimensional coefficients for a circular cross section. Hydrodynamic diameter: Diameter used to convert nondimensional coefficients [m]. If it is not given, the default is \(D = \sqrt{4 A_e / \pi}\), where \(A_e\) is the external cross-sectional area. The hydrodynamic diameter is also used for marine growth, for time domain VIV loads and in VIVANA. Nondimensional coefficients are only meaningful for a circular cross section. For any other shape, give dimensional coefficients. 3. Dimensional coefficients When Input code is Dimensional coefficients: CQx: Quadratic drag force coefficient per unit length in the tangential direction, \(C_{DX}\) [N·s2/m3]. CQy: Quadratic drag force coefficient per unit length in the normal direction, \(C_{DY}\) [N·s2/m3]. CLx: Linear drag force coefficient per unit length in the tangential direction, \(C_{DLX}\) [N·s/m2]. CLy: Linear drag force coefficient per unit length in the normal direction, \(C_{DLY}\) [N·s/m2]. CAx: Added mass per unit length in the tangential direction, \(m_{ax}\) [kg/m]. CAy: Added mass per unit length in the normal direction, \(m_{ay}\) [kg/m]. The units follow the unit system of the SIMA model. SIMA converts them to the export units of the RIFLEX task, see Export mass units. The tangential drag force per unit length, along the local x-axis, is \[F_t = C_{DX} \, v_x |v_x| + C_{DLX} \, v_x\] The normal drag force per unit length acts in the direction of the transverse relative velocity: \[F_n = C_{DY} \left( v_y^2 + v_z^2 \right) + C_{DLY} \sqrt{v_y^2 + v_z^2}\] where \(v_x\), \(v_y\) and \(v_z\) are the relative water velocities in the local x-, y- and z-directions. See Hydrodynamic load models for submerged elements for the full load formulation. 4. Nondimensional coefficients When Input code is Nondimensional coefficients, the same fields hold nondimensional coefficients: CQx: Nondimensional quadratic drag coefficient in the tangential direction, \(C_{dt}\). CQy: Nondimensional quadratic drag coefficient in the normal direction, \(C_{dn}\). CLx: Nondimensional linear drag coefficient in the tangential direction, \(C^L_{dt}\). CLy: Nondimensional linear drag coefficient in the normal direction, \(C^L_{dn}\). CAx: Nondimensional added mass coefficient in the tangential direction, \(C_{mt}\). CAy: Nondimensional added mass coefficient in the normal direction, \(C_{mn}\). It is normally 1.0 for a circular cross section. They are converted to dimensional coefficients by: \[C_{DX} = \tfrac{1}{2} \rho \, \pi D \, C_{dt}\] \[C_{DY} = \tfrac{1}{2} \rho \, D \, C_{dn}\] \[C_{DLX} = \rho \sqrt{g \pi D} \, (\pi D)^2 \, C^L_{dt}\] \[C_{DLY} = \rho \sqrt{g D} \, D^2 \, C^L_{dn}\] \[m_{ax} = \rho \frac{\pi D^2}{4} \, C_{mt}\] \[m_{ay} = \rho \frac{\pi D^2}{4} \, C_{mn}\] where: \(\rho\): Water density. \(g\): Acceleration of gravity. \(D\): Hydrodynamic diameter. \(\pi D\): Wetted perimeter of the cross section, which scales the tangential (friction) drag. 5. Froude-Krylov scaling When Froude-Krylov scaling is selected, the Froude-Krylov scaling section is shown: Tangential direction scaling: Scaling factor for the Froude-Krylov term in Morison’s equation in the tangential direction (default 1.0; only 0.0 and 1.0 permitted). Normal direction scaling: Scaling factor for the Froude-Krylov term in Morison’s equation in the normal direction (default 1.0; must not be negative). See Froude-Krylov scaling. With Time domain VIV, the tab also holds the time domain VIV load coefficients, see Loads due to vortex induced vibrations. Hydrodynamic Load Models Morison’s Generalized Equation