Cross-section properties

The Cross-section properties tab specifies the mass, volume and geometry data of an axisymmetric cross section.

um ii fig62
Figure 1. Axisymmetric cross section

1. Mass and volume

  • Mass coeff.: Mass per unit length

  • Ext. Area: External cross-sectional area. Used to calculate buoyancy

  • Int. Area: Internal cross-sectional area. Used to calculate the added mass of internal fluid if present, otherwise dummy

  • Gyration Radius: Radius of gyration about the local x-axis. Dummy for bar elements, i.e. cross sections with zero bending stiffness

If Ext. Area is zero, no buoyancy acts on the cross section. With the partly submerged load model, no hydrodynamic loads act on it either.

2. Thermal and pressure expansion

Select Default Thermal/Pressure Expansion to use the default thermal and pressure expansion settings, i.e. the value 0 for all three parameters. Clear the option to enter the values below.

  • Temperature: Temperature at which the specification applies

  • Alpha: Thermal expansion coefficient

  • Beta: Pressure expansion coefficient

Beta gives the expansion of an element with zero effective tension from the difference between the internal and the external pressure.

3. Contact radius and stress calculation input

Select Default contact radius and stress calculation input to use the default values described in this section. Clear the option to enter the values below.

  • Stress Calc. Area: Cross-section area for stress calculations

  • Stress Calc. Mod.: Cross-section modulus for stress calculations

  • Diameter: Diameter for stress calculations

  • Thickness: Thickness for stress calculations

  • Ext. Contact Rad.: External contact radius

  • In. Contact Rad.: Inner contact radius

3.1. Default stress calculation parameters

Default values of the stress calculation parameters are calculated from Ext. Area and Int. Area if Ext. Area > Int. Area. A homogeneous cylinder shaped cross-section is assumed:

  • Stress Calc. Area \(\mathrm {=AE-AI}\)

  • Stress Calc. Mod. \(\mathrm {=\pi (D_e^4-D_i^4)/(32D_e)}\)

  • Diameter \(\mathrm {=D_e}\)

  • Thickness \(\mathrm {=(D_e-D_i)/2}\)

where \(\mathrm {D_e=\sqrt{\frac{4AE}{\pi }}}\) and \(\mathrm {D_i=\sqrt{\frac{4AI}{\pi }}}\) are calculated from the external area (AE) and the internal area (AI).

3.2. Contact radii

The outer and inner contact radii of the cross section are used for

The default values of Ext. Contact Rad. and In. Contact Rad. are zero in the present version.