Bladed coupling

1. Bladed–SIMA co-simulation

The Bladed coupling enables co-simulation between Bladed by DNV and SIMA. Bladed simulates the wind turbine and integrates the motion of the floater. SIMA computes the hydrodynamic loads on the floater and the loads from the mooring system. At every time step, Bladed passes the floater motion at the coupling node to SIMA, and RIFLEX returns the floater loads at that node. This combines the turbine and controller models in Bladed with the floater and mooring models in SIMA. Bladed version 4.18 and onwards is supported by the coupling.

Bladed-SIMA co-simulation conceptual sketch
Figure 1. Bladed-SIMA co-simulation conceptual sketch

An example is listed under wind turbine examples: a SIMA floater model and a Bladed turbine model.

2. Requirements

The SIMA part of the coupling must be a RIFLEX task that contains the floater and mooring system. The model must meet these requirements:

  1. The model must have a single body, the floater.

  2. The body must not contain modelling elements that add to its mass, inertia or added mass. This includes the following modelling elements:

3. Prepare the SIMA model for coupled simulation

In a RIFLEX task that meets the requirements, make the following changes and export the model:

  1. Remove floater mass: Because Bladed integrates the floater motion, the floater mass, inertia and added mass must be modelled in Bladed, not in SIMA:

    1. Set Structural Mass of the floater body in SIMA to small dummy values, for example:

      Table 1. Dummy structural mass of the floater body
      Mass [kg] Ixx [kg m2] Iyx [kg m2] Iyy [kg m2] Izx [kg m2] Izy [kg m2] Izz [kg m2]

      1.0E-8

      1.0E-4

      0.0

      1.0E-4

      0.0

      0.0

      1.0E-4

    2. Delete Added Mass Infinite Frequency from the body’s Radiation Data.

  2. Fix the floater body: Set the constraint to Fixed on the supernode or Slender System Connection that the floater is attached to.

  3. Add a support vessel: Add a support vessel to the model and leave it unconnected.

    The coupling requires a support vessel but connects the floater to the slender system itself.
  4. Adjust Dynamic calculation: In Dynamic Calculation Parameters:

    1. Set Time Step equal to the integrator time step in Bladed.

    2. On the Procedure tab, set Start Up Duration to 0.

  5. Export model: Right-click the task, select Export > RIFLEX Input File(s), and select a folder. Set Identifier to sima.

    If the task editor uses non-default values for the RIFLEX memory parameters (Figure 2), the same values must be set in the Bladed model.
    RIFLEX memory parameters in the task editor
    Figure 2. RIFLEX memory parameters in the task editor

4. Configure the Bladed model

Start from an offshore floating Bladed model and make the following changes:

  1. Add the floater mass: Add the mass and inertia matrix of the floater in Bladed, normally under Additional Items > Added Inertias. Bladed then also applies the gravity load of the floater.

  2. Add the floater added mass: Bladed applies the added mass at infinite frequency, and SIMA all other hydrodynamic loads:

    1. In the tower screen, set Hydro loading model to BEM Hydrodynamics (without Morison drag) for every element, so that Bladed computes no Morison loads.

    2. Add a BEM body at the tower node at the floater’s reference point. This node will be referred to in the configuration of the coupling DLL as bladed_node_id.

    3. In the Hydrodynamics section, enable Calculate Radiation forces. Leave all other forces disabled.

    4. Enter the 6 × 6 added mass matrix at infinite frequency that was deleted from the SIMA body, in kg, kg m and kg m2.

    5. In the Common parameters section, disable the options Allow yaw rotation correction and Adjust Excitation Force Phases for Drift.

  3. Add a dummy mooring line: Bladed requires a mooring line in a floating model, and SIMA computes the mooring loads. Add one Tension Leg Mooring with a very low stiffness, for example 0.01 N/m. Select its fairlead in the Moorings column of the support structure and its anchor in Anchor Points. The positions have little effect, because the loads are small.

  4. Set the initial mooring position: In Calculation Parameters > Initial Conditions, select Define initial mooring position and enter the static position of the floater from SIMA (Find the static equilibrium position). Bladed does not call the External Loads DLL in its initial and steady calculations, so it cannot find the equilibrium itself. Bladed gives the orientation as an axis-angle rotation.

  5. Use a fixed-step integrator: The coupling requires a fixed time step. Set it equal to Time Step in the SIMA dynamic calculation parameters.

  6. Use the 64-bit solver: In File > Project info, click Define for Turbine calculations (dtbladed.exe) and select x64\dtbladed.exe. The coupling DLL is 64-bit.

  7. Add the coupling DLL: In Specify > Additional Items, open the External Loads DLLs window, select Use external loads DLL and add one instance. Set External Loads DLL Location to the coupling DLL and enter the parameters in Additional Parameters, as described in Coupling DLL and its parameters.

4.1. Coupling DLL and its parameters

The coupling DLL, bladed_sima_coupling.dll, is part of the SIMA installation:

<SIMA installation folder>
└── plugins
    └── no.sintef.ocean.sima.srv.bin.win32.x86_64_<version>
        └── riflex_simo
            └── bladed-coupling
                └── bladed_sima_coupling.dll

<version> is the version of the plugin, for example 4.23.0.v20261007-0822, and changes with every SIMA release. The installation has one such folder.

The Additional Parameters field takes a JSON object with the following keys:

Table 2. Keys of the Additional Parameters JSON object
Key Type Mandatory Description

sima_dir

String

Yes

Path to the SIMA installation folder.

riflex_model_dir

String

Yes

Path to the directory containing the exported RIFLEX input files.

coupling_supernode

String

Yes

Name of the supernode or slender system connection in the RIFLEX task that the floater is attached to.

bladed_node_id

Integer

Yes

Bladed tower node number to retrieve floater motion and apply floater loads to.

log_level

String

No

Detail of the coupling log, written to coupling.log in riflex_model_dir and to the Bladed log: off, error, warn, info, debug or trace (default info).

riflex_stamod_mem

Integer

No

Overrides default value of parameter RIFLEX Stamod Memory.

riflex_maxsta_ifnsta

Integer

No

Overrides default value of parameter RIFLEX Stamod Arrays (MAXSTA).

riflex_dynmod_mem

Integer

No

Overrides default value of parameter RIFLEX Dynmod Memory.

riflex_maxirr_ifnirr

Integer

No

Overrides default value of parameter RIFLEX Max Arrays (MAXIRR).

Example:

{
    "sima_dir": "C:/Program Files/DNV/Sima V5.4-00",
    "riflex_model_dir": "C:/path/to/exported/riflex/model",
    "coupling_supernode": "cpl",
    "bladed_node_id": 29
}

5. Find the static equilibrium position

Bladed needs the static equilibrium position of the floater as its initial mooring position.

The steps below assume that the Bladed node used as bladed_node_id is at the global origin of the Bladed model.

If the position is not known, compute it in SIMA with a model in which the floater and the turbine are one rigid body:

  1. Make the equilibrium model: Copy the RIFLEX task with the mooring system and the floater body. Set the constraint to Free on the supernode or Slender System Connection that the floater is attached to.

  2. Find the mass of the whole turbine in Bladed: Run a calculation with the Bladed model. Bladed writes the inertial properties of the turbine, floater included, to the verification file <run>.$VE in the output folder. Under Turbine Inertial Properties, Turbine 6x6 inertia matrix about global 0,0,0 has the same layout and signs as the structural mass matrix in SIMA:

    • Mass: the diagonal of the rows x, y and z.

    • Centre of gravity: Turbine centre of mass in global coordinates.

    • Ixx, Iyx, Iyy, Izx, Izy and Izz: the 3 × 3 block in the rows about x, about y and about z.

  3. Enter the mass in SIMA: Enter these values as the Structural Mass of the floater body.

  4. Run the static analysis: The static position of the floater body is its equilibrium position. Enter this position as the initial mooring position in Bladed, step 4 in Configure the Bladed model. In the coupled SIMA model, give the coupling node the same position as a static offset, so that SIMA and Bladed start from the same position. On the Parameter Variation tab of the static calculation parameters, select Static offset, set Reference type to Super node and select the coupling supernode, and enter the position in DX, DY and DZ and the rotation in Rotation code and Rotation increment. The static offset takes a rotation about one axis only, normally the pitch angle about the y-axis.

6. Simulation results

RIFLEX writes the results of the SIMA model to the folder given by riflex_model_dir. After the simulation has completed, results can be read in Python using SIMAPy. Individual .h5 result files can be imported back into SIMA using a File Input operation in a post processor or a File Input node in a workflow.