VIVANA modeling from scratch in SIMA

Goal: Analyze VIV responses of a top tensioned drilling riser.

1. Description of final system:

A tensioned riser subjected to a sheared current is modelled. The length of the riser is 612 m, which consists of sections of buoyancy elements and slick joints.

  • If you get confused with the window layout it is always possible to choose Window > Reset window layout.

  • If you make a mistake, type Ctrl+z to undo.

Prerequisites: Be in an open workspace

2. Create a new RIFLEX task

  • Right click in the browser, select New> RIFLEX Task

    • Name the task VIVANA_drilling in the wizard

  • Right click the VIVANA_drilling task and choose Open 3D View to open the graphics view

    • Zoom in on the the sea surface by clicking in the 3D-view and then using the scroll wheel of the mouse, or (when the mouse cursor is over the 3D graphics) by pressing and holding both the left and right buttons on the mouse and move it away from you. Pan the camera by pressing and holding the left mouse button and (while it is pressed) move it up/down/sideways.

  • Expand in the folder system browser to the right to see the different parts of the model

  • Under model folder, and location folder, double click on Flat bottom

  • Set position > z to –600 m to create a 600 m water depth.

  • Double click directly on the location folder

    • Set kinematic water depth to 600 m. This sets the hydrodynamic water depth used to calculate the hydrodynamic forces.

3. Create cross sections

  • Right click on folder Slender system and create New > Axisymmetric cross section

  • Axisymmetric cross section is a description of the cross section defined by outer and inner area of the pipe

    • Name it riserjoint_slick

  • Set the properties of the Riserjoint_slick

    • The temperature is set to default. We want this to be 20 degrees.

    • In the Cross-section properties tab

      • click the Default Thermal/Pressure Expansion check box to show the values table.

    • Right click on the default value for temperature and choose Set to editable. Set the value to 20.

    • Do the same for Alpha and Beta, and make sure the values are 0.0.

While in the Cross-section properties tab - set the following values:

Mass coeff Ext Area Int Area Gyration radius

179.45

0.19635

0.1735

0.1

In the Stiffness properties tab, set cross section type to Beam and choose No hysteresis.
Set stiffness types to Constant and set:

Axial stiffness Bending stiffness Shear stiffness Torsion stiffness

4.7092e+09

1.3858e+08

0

1e5

  • In the Hydrodynamic force coefficients tab, use Morison load formulation and set Input code to Dimensional coefficients. Set the following values:

CQy CAy

500

196

Let the rest of the coefficients be zero

  • In the Capacity parameters tab set the following values:

Tension capacity Max curvature

1.438e+07

0.4329

  • Right click on folder Slender System > Cross Sections > Thin-walled pipe cross section

    • Name it riserjoint_buoyancy

  • Set the properties of the Riserjoint_buoyancy:

Diameter Type Pipe Diameter Pipe Thickness Material Density Ext Coating Thickness Ext. Coating Density Ext Contact Radius Int. Contact Radius

Outer

0.5

0.015

7850.0

0.15

400.0

0.0

0.0

  • In the Material Properties tab, set the following values:

    • Material Model = Linear material

Elasticity Modulus Shear Modulus

2.06e+11

8.0e+10

  • In the Hydrodynamic force coefficients tab, set the following values:

CQy CAy

800

600

  • In the Capacity parameters tab set the following values:

Tension capacity Max curvature

1.438e+07

0.4329

4. Create supernodes

  • Right click on folder Slender system and create New > Supernode

    • Set name bottom_node

  • Set supernode bottom_node properties

    • Constraint: Fixed or prescribed

    • Initial Positions. The initial position always has to be set such that a line is unstretched. One only has to set either global or local position, the other will be calculated:

      • Click the Automatic Initial Position check box to reveal the initial position table. Set the following values:

Xg Yg Zg

0

0

–600

  • Static global position:

Xg Yg Zg

0

0

–600

  • Choose top boundary connection: Fix global X, Y and Z translation and Z rotation degree of freedom.

    • Right click on folder Supernodes and create New > Supernode

  • Set name top_node

    • Set supernode top_node properties

  • Constraint: Fixed or prescribed

  • Click the Automatic Initial Position check box to reveal the initial position table. The initial position has to be set such that a line is unstretched:

Xg Yg Zg

0

0

12

Fixed or Prescribed Configuration:

Static global position:

Xg Yg Zg

0

0

12

Choose top boundary connection: Fix global X and Y translations and Z rotation degree of freedom.

5. Create internal fluid

  • Right click on folder Slender system and create New > Internal Fluid

    • Set name internal_fluid

Set:

Density Flow Inlet

1400

End 1

6. Create a line type and a line

  • Right click on folder Slender system and create New > Line Type

    • Use default name riser_linetype

  • Set Line Type Properties

    • Create new segment by clicking the green plus under the segment line. Do this 3 times to create 3 segments

    • Set the lengths: The Stressfree length should be the same as the length of the segment.

segment 1 segment 2 segment 3

112

420

80

Set the number of elements:

segment 1 segment 2 segment 3

30

175

25

Set the first and last segments Cross section to riserjoint_slick. The middle segment has cross section: riserjoint_buoyancy
Set Internal fluid to internal_fluid.

  • Right click on folder Slender system and create New > Line

  • Set name: riser

Set properties:

Line Type End 1 End 2

riser_linetype

bottom_node

top_node

7. Create an environment

  • Right click on model and create New > Environment

  • Set Current to Current

    • Add two current levels by clicking the green plus sign twice, and set the following values:

No Level Direction Velocity

1

0

0

0.6

2

–600

0

0.1

  • Set Wave to Jonswap - 3 parameters

    • Set significant wave height to 2.0.

    • Set peak period to 3.0.

The Sima 3D view should now look like this:

image

8. Set static calculation properties

  • Set properties of Static Calculation under Calculation Parameters

    • In the Loading sequence tab, do the following:

    • Set Matrix storage to Skyline.

    • Set Load and Mass Formulation to Consistent load and mass formulation.

Click on the green plus icon to add Current forces, Tension contact forces and Specified forces.
Set values as shown in the following screen shot:
NB! The sequence of the load types must be as specified in the screen shot. Use the arrow icons under the table to move the load type items.

In the Load components tab, set the following values:
Add a line by clicking the green plus icon.

Line Segment Node/Element Dof Magnitude Reference Frame

riser

3

26

3

8.0e+05

Global

  • In the Parameter variation tab, do the following:

  • Check the Static offset increments check box.

  • Set num variations to 1.

  • Set max iterations to 15.

  • Set accuracy to 1.0e-05.

    • In the Offset variation section select the top_node supernode.

image

9. Set VIV calculation properties

  • Right click on the Calculation Parameters folder and add a new VIV calculation

  • In the Analysis Parameters tab set the following values:

VIV Load Type Response Frequency Option Damping

Cross-flow VIV loads are applied

Concurrent

0.01

10. Set Eigen Value Parameters

In the Eigenvalue Parameters tab, set the following values:

Number of eigenvalues Number of eigenvectors

40

40

11. Set Hydrodynamic Properties

  • In the Hydrodynamic Properties tab, click the green plus icon three times (once for each segment in the line type we have specified).

  • Open the Hydrodynamic coefficients section and set the water temperature to 5.0.

In the sub section Excitation zone properties, set the following values:

Name Min Max

gopal_

0.125

0.2

  • In the sub section Strouhal number properties, do the following:

    • Add a strouhal item (by clicking the plus sign) and select User defined curve.

    • Name it strouhal

  • Copy the values listed below and do the following:

    • In the properties table for the strouhal item select the drop down arrow next to the green plus icon, and select Create from clipboard.

      • This will add the below given values to the table.

40.0     0.1
100.0    0.18
200.0    0.19
400.0    0.195
1000.0   0.2
4000.0   0.205
10000    0.21
40000    0.215
1.0e+05  0.22
2.0e+05  0.4
3.0e+05  0.45
5.0e+05  0.45
8.0e+05  0.25
1.0e+06  0.23
4.0e+06  0.25
1.0e+07  0.27
  • In the table in the Hydrodynamic cross section properties section

    • Set excitation zone properties for all three rows to gopal

    • Set Strouhal number properties to strouhal for all three rows.

12. Fatigue Analysis

12.1. Specify the SN curves

Specify a SN-curve:

  • Right click on the model New > SN curve

  • Set the name of the SN curve to SN01

  • Set the slope to 4, i.e. m=4.0

  • Set the constant defining the SN curve to 15.01, i.e. log a =15.01

image

12.2. Set Fatigue Analysis Parameters

In the Fatigue Analysis tab, set the following values:

  • Set Calculation Option to Rainflow counting.

  • Set Num Cross Section Points to 4.

In the Cross section data section set the following values:

Axial Factor My Factor Mz Factor Cross Section Area Section Modulus Wall thickness

1.0

1.0

1.0

0.03045

0.003549

0.0

  • Add a SNCurve in the SN Curves section by clicking the green plus icon.

    • Name the SN Curve SNC01 and check the Included check box.

Set the following properties for this SN Curve:

Fatigue Limit Indicator Fatigue Limit Thickness Correction Thickness Correction Exponent First slope, m Constant, logC

No fatigue limit

0.0

0.0

0.0

4.0

15.01

13. Set dynamic calculation parameters

Open the Dynamic Calculation editor in the Calculation Parameters folder.

  • In the Storage tab, check the Visualisation responses check box in order to get a visual representation of the results.

14. Run the simulation

  • Run the simulation

    • Either double clicking the Initial condition Initial (under the Conditions folder) and click the Run vivana analysis button in the editor

image

or

  • By right clicking Inital (under the Conditions folder) and choose Run vivana analysis

image
  • If you have not opened the graphics view then open it by right clicking the task Vivana_drilling and choose Open 3D View

In the graphics view there are two drop down menus.

  • The first drop down contains the conditions in the task and will now only show Initial.

  • The second shows the Modeled state, the Static, the Dynamic and the VIV calculation results.

The Dynamic results is not a result of the VIVANA analysis. VIVANA is VIV in the time domain.

The results from the VIVANA analysis can be studied bu clicking on the Inital condition:

image

and by studying the file sima_vivana.mpf :

image